High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing

Product Details
Customization: Available
After-sales Service: Permanent
Warranty: 1years
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 8 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing
  • High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing
  • High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing
  • High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing
  • High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing
  • High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Exhibition
  • Equipment Site
  • Company Profile
Overview

Basic Info.

Model NO.
AC11kV-5000kW
Weight
11300kg
Work Place
Outdoor
Insulation Class
F
Communication Interface
RS485 RS232
Display Precision
Class 0.5
Power Factor
1
Way of Working
Continuous Working
Transport Package
Wooden Packaging
Specification
About 12192mm*2350mm*2591mm
Trademark
Triumph Load
Origin
Hebei
HS Code
9030339000
Production Capacity
15sets/Month

Product Description

Product Description

AC11kV-5000kW Load Bank
1)Control and Display: Load testing, local control (buttons), intelligent control, control interlock, one-key addition and reduction of load, local instrument display of data.

2)Software function: Manual loading, automatic loading, parallel testing (expanded function), real-time parameters, safety monitoring, data acquisition interval, data storage and query, graphical display.
 
3)Defensive function: Emergency stop, short circuit, over-voltage, temperature, fan interlock, fan air volume, fan phase sequence automatic conversion, protection switch, cabinet ground protection.
 
4)Surge protection function: The pseudo load cabinet is equipped with 10/350usI type test surge protector, the impact current is ≥15kA, and the UP value is ≤2.5kV.
 
5)Auxiliary function:The control panel of the load cabinet is equipped with a lighting switch, and a single-phase 220V/50Hz power socket is reserved for computers or other temporary power consumption.etc.
Detailed Photos
High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing

High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing

Product Parameters
Product
AC11kV-5000kW Intelligent Load Bank
Rating Voltage/Frequency AC 3-phase 3-wire AC11kV 50Hz/60Hz
Max Load Power Resistive power: 5000kW
Load Step
Resistive load: divided into 8 levels, They are: 200,400,400,500,500,1000,1000,1000kW
Instructions:
When the access voltage is lower than the rated voltage, the power of the load cabinet gear changes according to Ohm's law.
Load Tolerance(each gear) ±3%
Load Tolerance (overall) ±3%
Working Power 3 phase 5 wire External (A/B/C/N/PE)AC380V /50Hz About 85kw
Maximum protection class Control part IP56, alloy resistance power dissipation chamber IP21.
Wire Connection
Load Power Supply Input--Busbar (star connection)
Control power supply input--Terminal block
Use side or bottom access test cable, working power supply and remote control cable
Insulation Class F
Level of protection Overall IP54, power part IP21 when the tuyere is open, other IP54
Construction Container packaging, the box is equipped with personnel access door, and locked, Equipped with ladder access to the top, inlet/outlet wind protection door, A protective net is added inside to prevent foreign bodies from entering.
Communication Interface RS485,RS232
Working Mode Continuous Working
Cooling Forced air cooling, side air inlet, The top of the chassis is ventilated
Transportation Hoisting, the top of the chassis with load-bearing rings, in line with lifting and transportation conditions.
Chassis structure
Container packaging, the box is equipped with personnel access door, and locked,
It is equipped with a ladder that can reach the top, air inlet protection door, shutter configuration, and internal protective net to prevent foreign bodies from entering.
Color Grey (RAL7035)
Dimension About 12192mm×2350mm×2591mm (L × W × H)
Weight About 11300kg
Operating Environment Parameter
Work Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500M
Atmospheric Pressure 86~106kPa
High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing
Certifications

High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator TestingHigh Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing

Exhibition

High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator TestingHigh Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing

Equipment Site

High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing
High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator TestingHigh Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing

Company Profile
Kaixiang Technology was founded in 1994, focus on load 26 years! The Company is China's largest power testing and maintenance enterprise, the main power testing equipment research and development and manufacturing.
Kaixiang Technology is a Chinese high-tech enterprise, double soft certification enterprise, passed the ISO9001 international quality management system certification, CCS China Classification Society certification.The products have passed the EU CE certification, Russian Baiha EAC certification, and have been inspected by a number of testing institutions, and the technical indicators have met the requirements of quality standards. The company's current technical developers and technical service personnel account for more than 30%. It can provide users with full service from design, manufacturing, installation, commissioning, training to maintenance, as well as OEM/ODM, leasing and field testing services.

High Power 3 Phase 3 Wire AC 11kv 5000kw Load Bank for Generator Testing

1. Professional technical team with more than 20 years design experience.
2. Customer has the right of technical consulting service for free forever.
3. Drafters of load standards for the Marine industry
4. China's first ship load maximum power record holder
5. Reliable quality & competitive price help customers to maximize profits.
6. Strict inspection procedures throughout the whole production flow.
7. If required, technicians will be sent to help customer install and debug the machine.
8. Certified with CCS and ISO9001:2008 Quality Certificate.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier