AC10.5kV-500kW mining emergency generator set reverse power absorption device load bank
Technical Parameters | |
Rated Voltage /Frequency |
AC three-phase three-wire 10.5kV/50Hz |
Dry-type Transformers | SCB11-630kVA 10.5±2×2.5%/0.4kV |
Max Load Power | Rated resistive load totaling 500kW |
Load Step | Resistive Load:7 steps: 10, 20, 20, 50, 100, 100, 200kW |
Power Factor | 1 |
Load Tolerance (overall) | ±3% |
Display Precision | 0.5 class |
Control Power Supply | Circuit breaker control: DC220V |
Wire Connection | Load bank input--busbar (star coupling "Y") Control power input--terminal block Total alarm dry contact signal - wiring terminal block |
Communication Interface | Network interface |
Insulation Class | F Class |
Working Mode | Continuous Working |
Cooling | Forced air cooling, side inlet air, air duct outlet air. |
Chassis structure | Container type, equipped with a ladder that can reach the top. |
Casing Color | White(RAL9010) |
Dimension | About 11000mm×3000mm×2896mm |
Weight | About 12000KGS |
System response time | ≤600ms |
Response time of contactor | ≤180ms |
Lighting | There are lighting and power sockets inside. |
Protection of incoming and outgoing lines and ventilation openings | The inlet and outlet of the equipment cabinet have protective cover plates, which are waterproof when closed. Stainless steel protective nets are selected for the ventilation openings on both sides and the top air outlet to prevent foreign objects such as small animals from entering. |
Operating Environment Parameter | |
Workplace | Outdoor |
Work Temperature | -20ºC~+50ºC |
Relative Humidity | ≤95% |
Altitude | ≤2500M |
Atmospheric Pressure | 86~106kPa |
1. Load Testing: It can load any power within the rated value, measure and display the steady-state three-phase voltage, three-phase current, active power, reactive power, apparent power, power factor, frequency, operating time and other parameters of the tested equipment.
2. Control mode selection: you can choose the local or intelligent mode to control the load.
3. Local Control: There is local control panel with several power steps; user can load/unload by button.
4. Intelligent Control: Through data processing software in PC, user can make automatic load, to display, record and manage the testing data, to form curves, tables, also to print them.
5. Control Pattern Interlock, there is control pattern switch, when choose one control pattern, operation of other pattern is invalid, avoid the clash.
6. Load/unload with One Key: Whether manual control, remote control or software control, user can preset the power, then press load master button. Load bank loaded according to preset power to avoid load fluctuation during the power changing.
7. Local Meter Display Data: Three-phase voltage, three-phase voltage, active power, reactive power, apparent power, power factor and frequency parameters can be displayed through the local measuring instrument.
Protection:
(1) Manual emergency stop: If an emergency situation occurs during the operation of this machine, immediately press the red<emergency stop>switch, and the machine will unload all loads and sound an alarm. In this state, the loading function is locked and only the fan continues to run. After the emergency situation is resolved, the emergency stop switch can be rotated clockwise to unlock and retest.
(2) Automatic protection: This machine has an automatic protection function. When the following situations occur, the fault and corresponding alarm indicator lights will light up and sound an alarm, and all loads will be automatically unloaded. The protection state loading function is locked. Please investigate the cause and eliminate the fault. Wait for the alarm to be resolved before retesting.
Overheating: The internal temperature of the machine exceeds the preset warning line; Smoke: Smoke detected inside the machine;
Fan (air volume): The air volume of the fan is insufficient;
(3) Compulsory work: Some protection functions have switches, and the protection switch defaults to a downward protection state, at which point it can sound an alarm normally. When it is necessary to temporarily turn off certain protection functions and force the load to continue working, the corresponding protection switch can be turned up to [Off]. When encountering the corresponding situation, the alarm will no longer sound and the loading test can continue.
Attention: Do not perform any other operations on the measuring instrument except for the above functions, as incorrect settings may cause the instrument to become inaccurate.
If you have customization needs or would like to know more product details, please send me an inquiry
1. Kaixiang is the largest and earliest load bank manufacturer in China, we have 30 years experience. Our factory has 25,000 square meters.
2. The sole company that draw up the enterprise standard "Dry-type load bank" in China.
3. As the sole load bank supplier for China nuclear field and the largest load bank supplier for marine and aviation industry.
4. China Power Industry Top Ten Famous Products.
5. China Power Supply Recommend Products.
6. Certified by SGS, CE, ISO9001:2008.