  • AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank
  • AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank
  • AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank
  • AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank
  • AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank
  • AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank
Find Similar Products

Basic Info.

Model NO.
AC440V-5500kVA-RL
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
>2000Kg
Power Source
3p3w AC380V/50Hz or AC440V/60Hz
Cooling
Forced Air Cooling
Frequency
50/60Hz
Contactor
Schneide-R
Color
Ral7035 and Black
Transport Package
Wooden Crate
Specification
6058*2438*2896mm
Trademark
Triumph load
Origin
China
HS Code
903033
Production Capacity
1000

Product Description

Product Description

AC440V-5500kVA-RL Intelligent Testing System for Generator Set Load Bank

 

Main functions:

1. Users can set adjustable load power within rated power.
2. Current, voltage, frequency, power factor, and active power, reactive power, and apparent power can be displayed.

3. With software programmable control, graphs of current, voltage, frequency, power factor, power can be displayed, saved and printed.

Control mode: manual control (control panel) with remote controller box or PC control.

Display meters: multi-function digital meter or generator tester.

Protection: Over load protection, over heat protection, short circuit protection, Emergency stops switch, etc

 

Technical Parameters
Rated voltage/frequency
Star Triangle Conversion
AC three-phase three wire 440V; Frequency: 60Hz
At a voltage of AC three-phase three wire 690V; Frequency: At 50HZ, a star delta conversion circuit is used to achieve a power of 4800KVA
Max Load Power Resistive load 4400KW, inductive load 3300KVA, apparent power 5500KVA
Load Step
AC440V/60Hz

 
Resistive load: a total of 30 levels,
They are: 1KW, 2KW, 2KW, 5KW, 10KW, 10KW, 20KW, 50KW, 100KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW, 200KW
The minimum step value is 1kW, and the total power is 4400kW.
Sensory load: a total of 25 levels,
They are: 1KVA, 2KVA, 2KVA, 5KVA, 10KVA, 10KVA, 20KVA, 50KVA, 100KVA, 100KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA, 200 KVA
The minimum step value is 1kvar, and the total power is 3300kvar.
be careful:
When the input voltage is lower than the rated voltage, the load gear power decreases according to Ohm's law.
Power Factor Adjustable power factor is 0.2-1 (power factor at full load is 0.8-1)
Three phase balance of reactor ≤2%
Resistance three-phase balance ±3%
Load Tolerance (step) ±5%;
Load Tolerance (overall) ±3%
Display Precision 0.5 class
Load conversion method Adopting manual star angle load conversion mode;
Control Power Supply AC three-phase three wire AC380V/50Hz or AC three-phase three wire 440V/60Hz. The system's working power supply has an automatic phase sequence conversion function. Ship power and shore power can be manually selected.
Compatible voltage/frequency Angle connection method: three-phase three wire, AC440V/50Hz,
Apparent power: 4891kVA, active power: 3636kW, reactive power: 3272kvar.
Star connection method: three-phase three wire, AC690V/50Hz,
Apparent power: 4851kVA, active power: 3606kW, reactive power: 3246kvar.
Wire Connection Control power input--terminal block;
When using star connection method: load power input - copper bar (star connection method),
When using the corner connection method: load power input - copper bar (corner connection method).
Communication Interface RS485,RS232
Insulation Class F Class
Maximum protection level IP55 (control part)
Working Mode Continuous Working
Cooling Forced air cooling, side inlet and top outlet.
Chassis structure Container packaging, equipped with a detachable ladder and a dedicated grounding terminal,
The air inlet louvers are equipped with stainless steel mesh, and the top is an openable stainless steel door with stainless steel mesh inside
Transportation Lifting, the top of the chassis has load-bearing lifting rings for easy movement and transportation.
Casing Color RAL7035+ Black
Dimension About 6058mm×2438mm×2896mm
Weight About 22000KGS
Operating Environment Parameter
Workplace Outdoor
Work Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500M
Atmospheric Pressure 86~106kPa
Ventilation distance Require the air inlet to be unobstructed within 3-5 meters,
The air outlet should be at least 3 meters away from the roof or other obstacles.
Reserved distance For the convenience of personnel entry, there should be no obstacles within 3 meters in front of the control room,
There should be no obstacles 2 meters in front of the maintenance room.
Safe working distance There should be an isolation barrier 1 meter away from the load bank,
When the load bank is working, there should be no idle personnel within 3-5 meters
Protection function It has protection functions such as emergency stop, automatic overheating protection, automatic overcurrent protection, and automatic unloading of fan faults. The local load has sound and light alarms, and the machine software has alarm prompt functions such as fault alarms.
Load detection parameters Basic functions such as three-phase voltage, three-phase current, active power, reactive power, apparent power, power factor, frequency, and operating time
PC detection parameters The software displays basic parameters such as three-phase voltage, current, active power, reactive power, apparent power, power factor, frequency, and operating time, as well as functions such as fault alarm prompts.
Extended functionality 10 units of equal load can be operated in parallel, with automatic recognition and synchronous control for expanding the load.
Lighting This load has internal lighting and power sockets.
Electrical component brand The main electrical components are made by Schneide-r
Product Scope

AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load BankAC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank

Why Choosing Us?

1. Kaixiang is the largest and earliest load bank manufacturer in China, we have 30 years experience. Our factory has 25,000 square meters.

2. The sole company that draw up the enterprise standard "Dry-type load bank" in China.

3As the sole load bank supplier for China nuclear field and the largest load bank supplier for marine and aviation industry.

4. China Power Industry Top Ten Famous Products.

5. China Power Supply Recommend Products.

6. Certified by SGS, CE, ISO9001:2008.

7. Public company, as listed company in 2015.

  Partners
AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank


Company Information

Hebei Kaixiang Electrical Technology Co., Ltd is the largest and earliest load bank manufacturer in China, we have 30 years experience. 
AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank
AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank

 

AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank

Shows

AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank

 

Contact us
AC440V-5500kVA-Rl Intelligent Testing System for Generator Set Load Bank

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier