Act440V 100kw Automatic Load Bank for Generator Testing

Product Details
Customization: Available
After-sales Service: 3months-1year
Application: Electrical & Electronics
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 8 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Act440V 100kw Automatic Load Bank for Generator Testing
  • Act440V 100kw Automatic Load Bank for Generator Testing
  • Act440V 100kw Automatic Load Bank for Generator Testing
  • Act440V 100kw Automatic Load Bank for Generator Testing
  • Act440V 100kw Automatic Load Bank for Generator Testing
  • Act440V 100kw Automatic Load Bank for Generator Testing
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
440V 100kW
Power Factor
1
Voltage
440V
Key Word
Load
Workplace
Indoor
Frequency
50/60Hz
Power
100kw
Color
Oxide White
Specification
About 35kg
Trademark
Triumph Load
Origin
China

Product Description

ACT440V 100kW Automatic Load Bank for Generator Testing
Product Description

Introduction

Triumph load can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW.Resistive, inductive(reactive),capacitive or combined load banks can be customized for any application.
 
They can be used for testing numerous sets in a workshop environment, or used for on-site commissioning, witness tests and proof trials.Custom-built load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.
 
Triumph load are available in stationary type for permanent installation or portable type with fork lift pocket
base,castors.Larger load banks, typically above 1200kVA, are based on an ISO container construction. Special finishes including custom paint colors and stainless steel casings can be supplied.

Main functions

1. Users can set adjustable load power within rated power.
2. Current, voltage, frequency, power factor, and active power, reactive power, and apparent power can be displayed.
3. With software programmable control, graphs of current, voltage, frequency, power factor, power can be displayed, saved and printed.
Control mode: manual control (control panel) with remote controller box or PC control.
Display meters: multi-function digital meter or generator tester.
Protection: Over load protection, over heat protection, short circuit protection, Emergency stops switch, etc
Product show
Act440V 100kw Automatic Load Bank for Generator TestingAct440V 100kw Automatic Load Bank for Generator Testing
Product Parameters
Technical Parameters
Rating Voltage/Frequency AC three-phase four-wire 440V / 50Hz / 60Hz
Max Load Power Resistive Load:100kW
Load Step
(AC440V/50Hz)
Resistive Load:8 ,1,2,2,5,10,20,20,40kW
When the input voltage is lower than the rated value, the load bank power changes according to Ohm's law.
Power Factor 1
Load accuracy (complete machine) ±3%
Display precision Class 0.5
Control Power Supply External AC single-phase AC110~240V 50 / 60Hz / 1kW.
Wire Connection Load bank input--line bank  (Star connection)
Control power input--three core power socket.
 
Communication Interface RS485
Insulation Class F
Working Mode Continuous Working
Cooling Forced air cooing, horizontal inlet and outlet
carriage handle
Color White oxide
Dimension Abou 540mm×292mm×582mm(L*W*H)
Weight About 35kg
Operating Environment Parameter
Work Place Indoor
Work Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500M
Atmospheric Pressure 86~106kPa
Ventilation distance The air inlet is 1~2 meters without obstacles, The air outlet is high temperature, more than 3 meters away from the obstacles.
Safe working distance It shall be 1 meter outside the load cabinet, There shall be no miscellaneous personnel within 3-5 meters.
Company Profile
Act440V 100kw Automatic Load Bank for Generator Testing
Hebei Kaixiang Electrical Technology Co., Ltd is a leading manufacturer in emergency power supply test & maintenance industry.
Specialized in the design, R&D, manufacture of the high capacity AC & DC load bank, it owns the largest intelligent power supply testing equipment R & D centre in China.
 
The company's core technologies are independent research. there are seven patents, ten software copyrights and two corporate standards. It has been named the international advanced level scientific and technological achievements by Science and Technology Department of Hebei Province.
 
Kaixiang offer one-stop solutions to generator set & battery & UPS power manufacturers. Its products are widely used in data centre, shipbuilding, offshore platform, state grid, nuclear power, hospital, communication, railway, war industry etc filed.
Kaixiang is strategy partner of many famous company, such as Cummins, Caterpillar, Kohler, Jiangnan Shipyard, CSSC,CSIC, State grid, China mobile, Tecent, Baidu, Sinopec, CETC etc. Some of its products have been exported to America, Singapore, Israel, Japan, United Kingdom, Saudi Arabia, Australia, South Korea, Thailand, Sri Lanka, Angola etc. Through years of development, "Triumph Load" already the first brand in power supply detection industry in China.

Act440V 100kw Automatic Load Bank for Generator Testing
Certifications

Act440V 100kw Automatic Load Bank for Generator TestingAct440V 100kw Automatic Load Bank for Generator TestingAct440V 100kw Automatic Load Bank for Generator Testing


Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test,
Assist shipyard in mooring test,sea trial test.
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
To reduce "wet stacking" problems


Exhibition
Act440V 100kw Automatic Load Bank for Generator Testing
Model selection guide
Act440V 100kw Automatic Load Bank for Generator Testing
FAQ

Why choose us
1. Professional technical team with more than 20 years design experience.
2. Customized technical solutions meet customer's individual requirements.
3. Strict inspection procedures throughout the whole production flow.
4. Perfect after sales service create good user experience.
5. Reliable quality & competitive price maximize profits for customers.
6. Certified with CCS and ISO9001:2008 Quality Certificate.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier