Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing

Product Details
Customization: Available
Application: Electrical & Electronics
Color: Customized
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 8 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing
  • Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing
  • Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing
  • Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing
  • Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing
  • Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing
Find Similar Products

Basic Info.

Model NO.
DC480V 200A Load Bank
OEM
Available
Working Power Supply
AC Single-Phase 110/220V, 50/60Hz
Cooling
Forced Air Cooling
Total Voltage Precision
±1%
Current Precision
±1%
Ambient Temperature
-10ºC - +40ºC
Nominal Voltage
Customized
Communication Interface
RS232 USB
MOQ
1 Set
Trademark
Triumph Load
Origin
Hebei, China

Product Description

Product Description

 

Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing

Nominal Voltage

DC480V-200A

Battery Rated Voltage

DC480V

Discharge Voltage

Discharge at 10-600V.

MAX constant current 200A at 480V±10% (can discharge for long time).

Current will decrease if voltage falls.

Protected Voltage

10-600V

Discharge Current

1-200A

Discharge Time

1M---99H59M

Discharge Capacity

1-9999Ah

Constant current discharge control accuracy

±(0.3%+0.2A)

Control Precision

0.1V 0.1A

Working Power

Single phase 110/220V, 50/60Hz

Cooling

Forced air cooling

Work Temperature

-10ºC - +40ºC

Dimension

About 412mm*290mm*500mm(W*D*H)

Color

Customized

Weight

About 25kgs

DC Load Bank is the instrument that can maintain and capacity test to battery, DC power and UPS backup battery. Using the latest modern power electronic technology and intelligent micro-processing technology, cooperate with the computer data processing software, intelligent control battery discharge process, real-time monitor the battery pack. Easy to operation, after setting the parameters, it can test battery capacity automatically. It effectively reduce the maintenance work strength of the staff, improve the efficiency of maintenance test, reduce enterprise cost.

Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing

Main functions and features of DC Load Bank:

1.Display mode: LCD display, real-time display all testing data: voltage,current,capacity,discharge time and inner temperature of machine.

2.Control mode: SCM control, setting by keyboard: whole battery protection voltage,discharge current,discharge capacity,discharge time etc.

3.Autostop function:It will autostop under any of following reach the setting value: discharge time,capacity,protection voltage.

4.Protection function: When internal overheat,positive and negative is reverse,connection wire of the battery group is disconnected, it will unload and give a alarm. 

5.Real-time monitoring function: Real-time display and control all setting parameters(voltage,current,capacity,discharge time etc).

6. Record query function: It can reserve 8 group discharge data, user can query according to requirement.

7.Data transfer function: It equips with USB and RS232 interface, can use USB transfer the data or connect it to PC directly.

8.Data processing function: It equips with data processing software, can analysis and generate various curve chart automatically and support to print.

9.Computer remote control function: Can setting and revise discharge parameter by computer, it also can control the start and stop of the discharge.

10.Parallel operation function: It can parallel operation with above two sets of same models, each unit operation independently.

11.Calibration correction function: It can calibrate the total voltage and current of the battery.

12.Power consumption components: It adopts special alloy resistor, produce with patent technology, high power density, no naked flight, safe and reliable, long service live.

13.Integrated design:it adopts integrated design for the control circuit and power consumption components, with compact size, convenient to carry and it adopts forced air cooling.

Data processing software

The data processing software can analysis and processing the discharge information, then generate current curve graph, voltage curve graph, test data, and can output to Excel and Word, forming test reports, and support to print. According to these charts can view the performance of the battery pack change trend, provide scientific basis for judging the merits of the battery pack.

Company Information

 

Hebei Kaixiang Electrical Technology Co., Ltd is a leading manufacturer in emergency power supply test & maintenance industry. Specialized in the design, R&D, manufacture of the high capacity AC & DC load bank, it owns the largest intelligent power supply testing equipment R & D centre in China.

The company's core technologies are independent research. there are seven patents, ten software copyrights and two corporate standards. It has been named the international advanced level scientific and technological achievements by Science and Technology Department of Hebei Province.

Kaixiang offer one-stop solutions to generator set & battery & UPS power manufacturers. Its products are widely used in data centre, shipbuilding, offshore platform, state grid, nuclear power, hospital, communication, railway, war industry etc filed. Kaixiang is strategy partner of many famous company, such as Cummins, Caterpillar, Kohler, Jiangnan Shipyard, CSSC,CSIC, State grid, China mobile, Tecent, Baidu, Sinopec, CETC etc. Some of its products have been exported to America, Singapore, Israel, Japan, United Kingdom, Saudi Arabia, Australia, South Korea, Thailand, Sri Lanka, Angola etc. Through years of development, "Triumph Load" already the first brand in power supply detection industry in China.

Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing

Company structure

Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing

 

Certificate and qualification

Triumph Load Supply 200A DC Load Bank for Generator and UPS TestingTriumph Load Supply 200A DC Load Bank for Generator and UPS Testing

 

 

Packaging & Shipping

Triumph Load Supply 200A DC Load Bank for Generator and UPS Testing

 

Our Services
 

What We Can Do
1. Professional technical team with more than 20 years design experience.

2. Customized technical solutions meet customer's individual requirements.

3. Skilled workman insure the reliable assembly technology.

4. Strict inspection procedures throughout the whole production flow.

5. Prompt delivery & custom clearance make sure the customers receive the goods on time.

6. Perfect after sales service create good user experience.

7. Reliable quality & competitive price help customers to maximize profits.

8. Timely feedback save valued time for the customer.

9. Humanized management system build homelike work atmosphere.

10. Continuous devote to public welfare undertakings strive for harmonious society.


Exihibition hall

Triumph Load Supply 200A DC Load Bank for Generator and UPS TestingTriumph Load Supply 200A DC Load Bank for Generator and UPS Testing


Application

Large generator system testing in ocean engineering, drilling facilities,ship construction etc
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse
current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
To reduce "wet stacking" problems

Triumph Load Supply 200A DC Load Bank for Generator and UPS TestingTriumph Load Supply 200A DC Load Bank for Generator and UPS Testing

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now