400V 100kw Act Load Bank Portable Automatic PC for Power Testing

Product Details
Customization: Available
Warranty: 12 Months
Type: Load Bank
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 8 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • 400V 100kw Act Load Bank Portable Automatic PC for Power Testing
  • 400V 100kw Act Load Bank Portable Automatic PC for Power Testing
  • 400V 100kw Act Load Bank Portable Automatic PC for Power Testing
  • 400V 100kw Act Load Bank Portable Automatic PC for Power Testing
  • 400V 100kw Act Load Bank Portable Automatic PC for Power Testing
  • 400V 100kw Act Load Bank Portable Automatic PC for Power Testing
Find Similar Products

Basic Info.

Model NO.
ACT400V-100KW
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
0-100Kg
Power Source
AC110~240V
Cooling
Forced Air Cooling
Frequency
50/60Hz
Contactor
Schneide
Color
White
Transport Package
Wooden Crate
Specification
540*292*582mm
Trademark
Triumph load
Origin
China
HS Code
903033
Production Capacity
1000

Product Description

Product Description

 ACT400V 3 phase 100kW load banks

 

Technical Parameters
Rating Voltage/Frequency AC three-phase three-line 400V 50 / 60Hz (no zero line)
Max Load Power Resistive Load:100kW
Load Step
(AC400V/50Hz)
Resistive Load:8 ,1,2,2,5,10,20,20,40kW
When the input voltage is lower than the rated value, the load bank power changes according to Ohm's law.
Power Factor 1
Load Tolerance (overall) ±3%
Display precision Class 0.5
Control Power Supply External AC110-240V Single Phase  50/60Hz,About 1kW
Wire Connection Load power input -- fast plug (domestic rhinoceros socket); Control the power input -- three-core power socket.
Communication Interface RS485
Insulation Class F
Working Mode Continuous Working
Cooling Forced air cooing, horizontal inlet and outlet
Color White
Transport or move Haft
Dimension About 540mm×292mm×582mm(L*W*H)
Weight About 35kg
Operating Environment Parameter
Work Place Indoor
Work Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500M
Atmospheric Pressure 86~106kPa
Ventilation distance The air inlet is required to be 1 ~ 2 meters free of obstacles.
High temperature of air outlet, obstacle more than 3 meters.
Safe working distance There should be an isolation fence 1 meter away from the load cabinet.
When the load cabinet is working, there should be no idle personnel within 3-5 meters.

Function:
1. Load test: any power within the rated value can be loaded to measure and display the steady-state three-phase current, active power, power factor, frequency, operating time and other parameters.
2.Control mode: user can choose local manual control , or Intelligent control(PC control).
3. Local control: through the switches and instruments on the local control panel, carry out the manual loading / unloading control of the load bank and view the test data.
4. Intelligent controlWith data processing software, could form curve of current, active power, reactive power, apparent power, power factor, frequency and can be printed.
5. Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.
6. One-key load/ unload: using manual control or software control, preset the power value first, and then Starting master switch, the load bank will be loaded according to the preset value, so as to avoid the load fluctuation in the process of power adjustment.
7. Data display: it could display Three phase voltage, three-phase current, active power, reactive power, apparent power, power factor, frequency and other parameters.
 

Protection:Emergency StopOver voltage ProtectionOverheating ProtectionFan Interlock Protection; Chassis Grounded Protection

 

If you have customization needs or would like to know more product details, please send me an inquiry


Product Scope

400V 100kw Act Load Bank Portable Automatic PC for Power Testing

Why Choosing Us?

1. Kaixiang is the largest and earliest load bank manufacturer in China, we have 30 years experience. Our factory has 25,000 square meters.

2. The sole company that draw up the enterprise standard "Dry-type load bank" in China.

3As the sole load bank supplier for China nuclear field and the largest load bank supplier for marine and aviation industry.

4. China Power Industry Top Ten Famous Products.

5. China Power Supply Recommend Products.

6. Certified by SGS, CE, ISO9001:2008.

7. Public company, as listed company in 2015.

  Partners
400V 100kw Act Load Bank Portable Automatic PC for Power Testing


Company Information

Hebei Kaixiang Electrical Technology Co., Ltd is the largest and earliest load bank manufacturer in China, we have 30 years experience. 
400V 100kw Act Load Bank Portable Automatic PC for Power Testing
400V 100kw Act Load Bank Portable Automatic PC for Power Testing

 

400V 100kw Act Load Bank Portable Automatic PC for Power Testing

Shows

400V 100kw Act Load Bank Portable Automatic PC for Power Testing

 

Contact us
400V 100kw Act Load Bank Portable Automatic PC for Power Testing

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier