48V 100A DC Load Bank for Battery Dischargetesting

Product Details
Customization: Available
After-sales Service: 3months-1year
Application: Electrical & Electronics
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 8 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • 48V 100A DC Load Bank for Battery Dischargetesting
  • 48V 100A DC Load Bank for Battery Dischargetesting
  • 48V 100A DC Load Bank for Battery Dischargetesting
  • 48V 100A DC Load Bank for Battery Dischargetesting
  • 48V 100A DC Load Bank for Battery Dischargetesting
  • 48V 100A DC Load Bank for Battery Dischargetesting
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
48V 100A
Color
Grey
Key Word
Load
Voltage
48V
Current
100A
Customized Support
OEM
Function
Battery Discharge Testing Load Bank
Specification
About 25kg
Trademark
Triumph Load
Origin
China

Product Description

48V 100A  DC Load Bank for Battery DischargeTesting
Product Description

Main features

Display mode: LED displays voltage, current, capacity, and duration.
Control method: Setting protection voltage, discharge current, discharge capacity, and discharge duration of battery pack through the keyboard.

Protection function: when internal temperature of the machine is overheated, device automatically cut off. When the positive and negative poles are reversely connected and the battery pack connection is disconnected, automatically alarm and cut off .
The last parameter data can be automatically stored to avoid repeated setting of parameters when the battery pack of the same model is discharged repeatedly.

Product show
48V 100A DC Load Bank for Battery Dischargetesting
Product Parameters
Nominal Voltage DC48V
Discharge Voltage Discharge at 5-60V, DC4810% for MAX current 100A (can discharge for long time). Current will decrease if voltage falls.
Protected Voltage 5-60V
Discharge Current 1-100A
Discharge Time 1M---99H59M
Discharge Capacity 1-9999Ah
Voltage current accuracy ±1%
Accuracy Current 0.1A, Voltage 0.1V
Working Power External AC single-phase 220V ± 10% 50Hz
Cooling Forced air cooling
Ambient Temperature -10ºC - +50ºC
Company Profile

Company information

Hebei Kaixiang Electrical Technology Co.Ltd is a leading manufacturer in emergency power supply test & maintenance industry.Specialized in the design,R&D, manufacture of the capacity AC & DC load bank,it owns the largest intelligent power supply testing equipment R & D center in China.
 
The company's core technologies are independent research. There are ten patents,ten software copyrights and two corporate standards.It has been named the international advanced level scientific and technological achievements by Science and Technology Department of Hebei Province.
 
Kaixiang offer one-stop solutions to generator set & battery & UPS power manufacturers.Its products are widely used in data center,shipbuilding,offshore platform,state grid,nuclear power, hospital ,communication,railway,war industry etc filed.Kaixiang is strategy partner of many famous company,such as Cummins, Caterpillar, Kohler, Jiangnan Shipyard, CSSC,CSIC, State grid, China mobile, Tecent, Baidu, Sinopec, CETC etc. Some of its products have been exported to America, Singapore, Israel,Japan, United Kingdom, Saudi Arabia, Australia, South Korea,Thailand, Sri Lanka, Angola etc. Through years of development, "Triumph Load" already the first brand in power supply detection industry in China.
48V 100A DC Load Bank for Battery Dischargetesting
Certifications

48V 100A DC Load Bank for Battery Dischargetesting48V 100A DC Load Bank for Battery Dischargetesting

Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test,
Assist shipyard in mooring test,sea trial test.
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
To reduce "wet stacking" problems

Our workshop
48V 100A DC Load Bank for Battery Dischargetesting
FAQ

Why choose us
1. Professional technical team with more than 20 years design experience.
2. Customized technical solutions meet customer's individual requirements.
3. Strict inspection procedures throughout the whole production flow.
4. Perfect after sales service create good user experience.
5. Reliable quality & competitive price maximize profits for customers.
6. Certified with CCS and ISO9001:2008 Quality Certificate.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier