• 200kw Resistive Load Bank Customized Variable for Generator Testing
  • 200kw Resistive Load Bank Customized Variable for Generator Testing
  • 200kw Resistive Load Bank Customized Variable for Generator Testing
  • 200kw Resistive Load Bank Customized Variable for Generator Testing
  • 200kw Resistive Load Bank Customized Variable for Generator Testing
  • 200kw Resistive Load Bank Customized Variable for Generator Testing

200kw Resistive Load Bank Customized Variable for Generator Testing

Application: Electrical & Electronics
Product Name: Load Bank
Function: Testing
Voltage: 415V
Power Factor: 1
Color: Customized
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2014

Suppliers with verified business licenses

Hebei, China
to see all verified strength labels (25)

Basic Info.

Model NO.
AC415V-200kw Load Bank
Power
200kw
Size
300mm*540mm*580mm
Weight
40kg
Cooling
Air Forced
Trademark
Triumph Load
Origin
China

Product Description

Product Description

 

Technical Parameters

Rating Voltage/Frequency

AC415V 3 Phase 4 Wire /50Hz/60Hz

Max Load Power 

Resistive Load:200kW

Load Step

(AC415V/50Hz)

Resistive Load:9 steps,1,2,2,5,10,20,40,40,80kW

Noted: When input voltage is lower than rated voltage, gears power changes according to Ohm's law.

Power Factor

1

Load Tolerance (overall)

±3%

3 Phase Unbalance

3%

Display precision

Class 0.5

Control Power Supply

External: AC220-240V single phase/ 50Hz

Wire Connection

Load bank input--Busbar (star coupling "Y")

Control power input--3-pin socket

Communication Interface

RS485

Insulation Class

F

Working Mode

Continuous Working

Cooling

Forced air cooing, horizontal inlet and outlet

Transportation

With lifting eyes and wheel castors at bottom

Color

White oxide

Dimension

About 300mm*540mm*580mm(L*W*H)

Weight

About 40kg

Operating Environment Parameter

Work Place

Indoor

Work Temperature

-20ºC~+50ºC

Ventilation distance

Require 3 to 5 meters of air inlet without obstacle.

The air outlet is more than 3 meters away from obstacles.

Relative Humidity

≤95%

Altitude

≤2500M

Atmospheric Pressure

86~106kPa

200kw Resistive Load Bank Customized Variable for Generator Testing

Certificate and qualification
200kw Resistive Load Bank Customized Variable for Generator Testing200kw Resistive Load Bank Customized Variable for Generator Testing

Company Information

 Company introduction

Hebei Kaixiang Electrical Technology Co., Ltd is a leading manufacturer in emergency power supply test & maintenance industry. Specialized in the design, R&D, manufacture of the high capacity AC & DC load bank, it owns the largest intelligent power supply testing equipment R & D centre in China.

The company's core technologies are independent research. there are seven patents, ten software copyrights and two corporate standards. It has been named the international advanced level scientific and technological achievements by Science and Technology Department of Hebei Province.

Kaixiang offer one-stop solutions to generator set & battery & UPS power manufacturers. Its products are widely used in data centre, shipbuilding, offshore platform, state grid, nuclear power, hospital, communication, railway, war industry etc filed. Kaixiang is strategy partner of many famous company, such as Cummins, Caterpillar, Kohler, Jiangnan Shipyard, CSSC,CSIC, State grid, China mobile, Tecent, Baidu, Sinopec, CETC etc. Some of its products have been exported to America, Singapore, Israel, Japan, United Kingdom, Saudi Arabia, Australia, South Korea, Thailand, Sri Lanka, Angola etc. Through years of development, "Triumph Load" already the first brand in power supply detection industry in China.

200kw Resistive Load Bank Customized Variable for Generator Testing

Company structure

200kw Resistive Load Bank Customized Variable for Generator Testing

Packaging & Shipping

200kw Resistive Load Bank Customized Variable for Generator Testing200kw Resistive Load Bank Customized Variable for Generator Testing

Exihibition hall

200kw Resistive Load Bank Customized Variable for Generator Testing

200kw Resistive Load Bank Customized Variable for Generator Testing

Application

Large generator system testing in ocean engineering, drilling facilities,ship construction etc
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse
current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
To reduce "wet stacking" problems

200kw Resistive Load Bank Customized Variable for Generator Testing

200kw Resistive Load Bank Customized Variable for Generator Testing200kw Resistive Load Bank Customized Variable for Generator Testing

FAQ

 Why choosing us
1. Professional manufacturer of AC/DC Load Bank in China, dedicated to this industry for more than 20 years.
2. Lot of patent technology and scientific research awards gainer in China.
3. Advanced detection method and strict inspection procedure build the qualified quality.
4. Customized production meet the individual requirement.
5. Prompt delivery & excellent after sales service.
6. Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
7. Certified with China Classification Society (CCS) and ISO9001:2015 Quality Certificate.
8. Triumph Load is the famous brand in the emergency power supply test & maintenance industry in China.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2014

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
193
Year of Establishment
2005-01-11