230V 20kw AC Rack Mounted Load Bank for Data Center Testing

Product Details
Customization: Available
After-sales Service: 3months-1year
Application: Electrical & Electronics
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 8 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • 230V 20kw AC Rack Mounted Load Bank for Data Center Testing
  • 230V 20kw AC Rack Mounted Load Bank for Data Center Testing
  • 230V 20kw AC Rack Mounted Load Bank for Data Center Testing
  • 230V 20kw AC Rack Mounted Load Bank for Data Center Testing
  • 230V 20kw AC Rack Mounted Load Bank for Data Center Testing
  • 230V 20kw AC Rack Mounted Load Bank for Data Center Testing
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
230V 20kW
Power Factor
1
Workplace
Indoor
Voltage
230V
Frequency
50/60Hz
Key Word
Load
Color
Black
Rated Power
20kw
Specification
About 32kg
Trademark
Triumph Load
Origin
China

Product Description

230V 20kW AC  Rack Mounted Load Bank for Data Center Testing
Product Description

Introduction

Triumph load can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW.Resistive, inductive(reactive),capacitive or combined load banks can be customized for any application.
They can be used for testing numerous sets in a workshop environment, or used for on-site commissioning, witness tests and proof trials.Custom-built load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.
Triumph load are available in stationary type for permanent installation or portable type with fork lift pocket
base,castors.Larger load banks, typically above 1200kVA, are based on an ISO container construction. Special finishes including custom paint colors and stainless steel casings can be supplied.

Main functions
(1)Load test: It can load any power within the rated value, simulate the actual heating condition of the server in the computer room, and test the cooling effect of the precision air conditioner, the load carrying capacity of the power supply, and the reliability of the circuit.
(2) Control mode: The load is equipped with 1 fan switch and 8 gear air switches, which can be controlled by 8 miniature circuit breakers.
(3) Fan power supply: The fan is installed near the air outlet. After the power is connected, flip the fan switch and the fan starts to rotate. And then through the gear gap combination to add/remove load to achieve power/load.
(4) Power indicator: There is a power indicator on the panel. After the input power is plugged in, if the load is charged, the power indicator will light up to remind the user that the device has been charged to avoid electric shock.
(5) Temperature protection: when the load temperature exceeds the safety threshold (85 ºC), the audible and visual alarm will prompt and cut off the load.

Product show
230V 20kw AC Rack Mounted Load Bank for Data Center Testing230V 20kw AC Rack Mounted Load Bank for Data Center Testing
Product Parameters
Technical Parameters
Rated Voltage
/Frequency
AC single-phase 230V 50/60Hz
Rated power Resistive load:20kW
Load Step divided into 7 interfaces; A (FAN, 1kW, 1kW), B (3kW), C (3kW), D (3kW), E (3kW), F (3kW), G (3kW);
Note: When used below the rated voltage, the gear power decreases according to Ohm's law.
Power Factor 1
Load accuracy (per gear)  ±5%
Load accuracy (whole machine) ±3%
Control power supply Internal interface A
Wire Connection Load power supply input is -- C20.
Insulation Class F
Duty Cycle Continuous
Cooling Forced air cooling, forward wind, after the wind. No air inlet and outlet shall remain on the side of the chassis.
Casing Color black
Dimension 10U, about 431mmx500mmx444.45mm (W * D * H)
Weight About 32kg
Transportation Front panel with handle and removable hanging ears on both sides.
defencive function 1, emergency stop, short circuit, temperature, chassis grounding protection;
2, each interface can be connected to different phase power supply;
3. When port A is powered off, it cannot be loaded.
Operating Environment Parameter
work environment indoor
Work Temperature -20ºC~+50ºC.
Storage environment 95%
Altitude 2500M
Atmospheric Pressure 86~106kPa
 
Company Profile

Company introduction

Hebei Kaixiang Electrical Technology Co.Ltd is a leading manufacturer in emergency power supply test & maintenance industry.Specialized in the design,R&D, manufacture of the capacity AC & DC load bank,it owns the largest intelligent power supply testing equipment R & D center in China.
 
The company's core technologies are independent research. There are ten patents,ten software copyrights and two corporate standards.It has been named the international advanced level scientific and technological achievements by Science and Technology Department of Hebei Province.
 
Kaixiang offer one-stop solutions to generator set & battery & UPS power manufacturers.Its products are widely used in data center,shipbuilding,offshore platform,state grid, nuclear power, hospital ,communication,railway,war industry etc filed.Kaixiang is strategy partner of many famous company,such as Cummins, Caterpillar, Kohler, Jiangnan Shipyard, CSSC,CSIC, State grid, China mobile, Tecent, Baidu, Sinopec, CETC etc. Some of its products have been exported to America, Singapore, Israel,Japan, United Kingdom, Saudi Arabia, Australia, South Korea,Thailand, Sri Lanka, Angola etc. Through years of development, "Triumph Load" already the first brand in power supply detection industry in China.
230V 20kw AC Rack Mounted Load Bank for Data Center Testing
Certifications

230V 20kw AC Rack Mounted Load Bank for Data Center Testing230V 20kw AC Rack Mounted Load Bank for Data Center Testing

Application

Large generator system testing in ocean engineering, drilling facilities,ship construction etc
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test,
Assist shipyard in mooring test,sea trial test.
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
To reduce "wet stacking" problems

Exhibitions
230V 20kw AC Rack Mounted Load Bank for Data Center Testing
FAQ

Why choose us
1. Professional technical team with more than 20 years design experience.
2. Customized technical solutions meet customer's individual requirements.
3. Strict inspection procedures throughout the whole production flow.
4. Perfect after sales service create good user experience.
5. Reliable quality & competitive price maximize profits for customers.
6. Certified with CCS and ISO9001:2008 Quality Certificate.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier