3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank

Product Details
Customization: Available
Application: Electrical & Electronics
Color: According to Customers′prefer
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 8 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • 3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank
  • 3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank
  • 3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank
  • 3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank
  • 3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank
  • 3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank
Find Similar Products

Basic Info.

Model NO.
AC400V-3500kw Load Bank
Dimension
6058mm*2350mm*2591mm
Weight
7000kgs
Ambient Temperature
-20ºC~+50ºC
PLC
Siemens
Cooling
Forced Air Cooling
Trademark
Triumph Load
Origin
China
Production Capacity
100 Set/Sets Per Month

Product Description

Product Description

 

Electrical variable diesel generator load bank 3500kW AC resistive load bank for generator and UPS testing

Introduction

(1) According to the special requirements of users on site, in the agreement the technical standards of AC400-3.5MW Resistive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator, UPS load test.

(2) The system consists of 1 sets of 3.5MW Resistive load bank. The resistive power is 3.5MW. The System is made up of two parts of measurement and control and load, mainly including the outdoor type dry load, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote controller and PC software and so on.

(3)This system, which is of independent research and development of electricity load test equipment by our technology, combining dry load module with the automatic measurement and control module, can accurately detect all kinds of generator output power and load capacity, full load and overload test.

The system can be used with a computer to realize the intelligent control, automatically completing the special test to all electrical parameters of generating set and generating tables, graphs, and supporting the print, comprehensively from the cumbersome manual operation to provide scientific and efficient detection means for the power generating sets.

(4) All the schematic diagrams of this agreement are for reference only please in kind prevail

Specification

Technical Parameters

Rating Voltage/Frequency

AC380V 3 phase 5wire ,50Hz

Max Load Power

Resistive Load: 3510kW

Load Step (AC380V/50Hz)

Resistive load: The local panel uses a touch screen, can set the loading phase, can move the input power or split mode, with USB interface, can export data. File as follows,

They are:1,2,2,5,10,20,20,50,100,100,200kW*16.

Instructions:

1)When the test voltage is lower than the rated voltage, the power of the load cabinet gear changes according to Ohm's law.

Power Factor

1

Load Tolerance(overall)

±3%

Three-phase unbalance

≤3%

Display precision

Class 0.5

Control Power Supply

Internal and external AC three-phase five wire(A/B/C/N/PE)AC380V 50Hz/ About 45kW;

Internal and external connection selection using the working power supply selection switch selection;

Instrument displays working power when connected.

Wire Connection

Load power input - P3 quick plug (10 per phase, 10 neutral lines, 5 ground lines);

Control power input - internal and external connection, external connection using wiring bar.

Communication Interface

RS485,RS232

Insulation Class

F

Maximum protection class

Control part IP55, alloy resistance power dissipation chamber IP21.

Working

Continuous operation

Cooling

Forced air cooling, side inlet air, wind from both sides of the duct.

Transportation

For hoisting, the chassis is provided with a load-bearing lifting ring at the top Meet the lifting and transportation conditions.

Case construction

Container packaging, the box is equipped with personnel access door, and locked,

It is equipped with a ladder to reach the top, air intake protection cover plate, and internal protection net.

Color

RAL7035

Dimension

About 6058mm*2438mm*2591mm (L*W*H)

Weight

About 8000kg

Operating Environment Parameter

Work place

outdoor

Temperature

-20ºC~+50ºC

Relative Humidity

≤95%

Altitude

≤2500m

Atmospheric Pressure

86~106kPa

Ventilation distance

The air inlet is required to be 3 to 5 meters free of obstacles.

The air outlet is more than 3 meters away from the roof or other obstacles.

Reserved distance

In order to facilitate access, there should be no obstacles 3 meters in front of the control room.

There should be no obstacles 2 meters in front of the maintenance room.

Safe working distance

There should be an isolation fence 1 meter away from the load cabinet.

When the load cabinet is working, there should be no idle personnel within 3-5 meters.

Certificate and qualification
3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank
Company Information

 

Company introduction

Hebei Kaixiang Electrical Technology Co., Ltd is a leading manufacturer in emergency power supply test & maintenance industry. Specialized in the design, R&D, manufacture of the high capacity AC & DC load bank, it owns the largest intelligent power supply testing equipment R & D centre in China.

The company's core technologies are independent research. there are seven patents, ten software copyrights and two corporate standards. It has been named the international advanced level scientific and technological achievements by Science and Technology Department of Hebei Province.

Kaixiang offer one-stop solutions to generator set & battery & UPS power manufacturers. Its products are widely used in data centre, shipbuilding, offshore platform, state grid, nuclear power, hospital, communication, railway, war industry etc filed. Kaixiang is strategy partner of many famous company, such as Cummins, Caterpillar, Kohler, Jiangnan Shipyard, CSSC,CSIC, State grid, China mobile, Tecent, Baidu, Sinopec, CETC etc. Some of its products have been exported to America, Singapore, Israel, Japan, United Kingdom, Saudi Arabia, Australia, South Korea, Thailand, Sri Lanka, Angola etc. Through years of development, "Triumph Load" already the first brand in power supply detection industry in China.

3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank

Company structure

3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank

 

Packaging & Shipping

3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank

Our Services

 

What We Can Do
1. Professional technical team with more than 20 years design experience.

2. Customized technical solutions meet customer's individual requirements.

3. Skilled workman insure the reliable assembly technology.

4. Strict inspection procedures throughout the whole production flow.

5. Prompt delivery & custom clearance make sure the customers receive the goods on time.

6. Perfect after sales service create good user experience.

7. Reliable quality & competitive price help customers to maximize profits.

8. Timely feedback save valued time for the customer.

9. Humanized management system build homelike work atmosphere.

10. Continuous devote to public welfare undertakings strive for harmonious society.

Exihibition hall

3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank

Application

Large generator system testing in ocean engineering, drilling facilities,ship construction etc
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse
current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing
The acceptance of new system and testing of servicing equipment
To reduce "wet stacking" problems


3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank3500kw AC Resistive Load Bank for Generator and UPS Testing Electrical Variable Diesel Generator Load Bank

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier