AC400V-20kw Rack Mounted Load Bank

Product Details
Customization: Available
After-sales Service: Permanent
Warranty: 1years
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 8 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • AC400V-20kw Rack Mounted Load Bank
  • AC400V-20kw Rack Mounted Load Bank
  • AC400V-20kw Rack Mounted Load Bank
  • AC400V-20kw Rack Mounted Load Bank
  • AC400V-20kw Rack Mounted Load Bank
  • AC400V-20kw Rack Mounted Load Bank
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Exhibition
  • Equipment Site
  • Company Profile
Overview

Basic Info.

Model NO.
AC400V-20kW
Weight
32kg
Work Place
Outdoor
Color
Black
Transport Package
Wooden Packaging
Specification
About 431mm*444.5mm*500mm
Trademark
Triumph Load
Origin
Hebei
HS Code
9030339000
Production Capacity
15sets/Month

Product Description

Product Description
Rack-mounted Load Bank
Application: mainly used to replace server as terminal load, simulating heat source of rack-mounted server, and to assist testing of air conditioner in data center server room, nodes line, PDU, generator set, UPS power supply, etc.
Types: Resistive(R), Inductive(L), Capacitive (C) nal
Voltage: 160-240VAC/50Hz;180-300VDC; AC, DC or combined Work mode: constant current or constant power.

AC400V 20kW Rack Mounted Load Bank
1) Load test: It can load any power within rated power, and simulate the actual heating of server in the computer room to detect cooling effect of precision air conditioning, the power supply capacity and the reliability of circuit.

2)Control mode: The load is equipped with 8 micro circuit breakers and 1 fan switch, which can control loading and unloading through 8 micro circuit breakers.
 
3)Fan power supply: After the power connection is completed, switch the fan switch, the fan starts, and the power increase and decrease control is realized through the combination of 8 gear micro circuit breaker loading/unloading.
 
4)Temperature protection: When the load temperature exceeds the safety threshold (85 ° C), the audible and visual alarm prompts and cuts off the load.
 
5)Load cable: Internal cable adopts multi-core flame retardant flexible wire, and added glass fiber sleeve protection, etc.
Detailed Photos

AC400V-20kw Rack Mounted Load BankAC400V-20kw Rack Mounted Load BankAC400V-20kw Rack Mounted Load Bank

Product Parameters
Product
AC400V 20kW Rack Mounted Load Bank
Rating Voltage/Frequency AC three-phase five wire (3P+N+ground), AC400V 60Hz
Rated Power Resistive Load: 20kW@ 400V/60Hz
Wire Connection
They are:1kW, 1kW, 1kW, 1kW, 4kW, 4kW, 4kW, 4kW, 
Instructions:
When the input voltage is lower than the rated voltage, the load cabinet gear position power varies according to Ohm's law.
Interface description 1. Chassis rear panel; The input interface is the terminal block; Test cable load terminal connector is copper nose;
2. The load adopts manual control mode, equipped with 9 circuit breakers, including 1 fan control and 8 gear control;
Power Factor 1
Load accuracy (per gear) ±5%
Load Tolerance (overall) ±3%
Working Power Supply Terminal block
Insulation Class F
Protection Class IP20
Working Mode Continuous Working
Cooling Forced air cooling, intake air in front and exhaust cooling in back
No air intake or exhaust vents are allowed in other positions.
Transportation The front panel mounting handle is transportable hanging ears
Color Black
Dimension 19 inches, 10U
About 431mm×444.5mm×500mm (L × W × H)
Weight About 32kg
Operating Environment Parameter
Work Temperature -10ºC~+40ºC
Storage environment  -15°C to +50°C; 20%RH to 90%RH.
Altitude ≤1500M
Atmospheric Pressure 86~106kPa
 
Certifications

KX is a high-tech enterprise certified by CCS ISO9001 International Quality Management System. The product has passed the CE certification.

AC400V-20kw Rack Mounted Load BankAC400V-20kw Rack Mounted Load Bank

Exhibition

AC400V-20kw Rack Mounted Load BankAC400V-20kw Rack Mounted Load Bank

Equipment Site

AC400V-20kw Rack Mounted Load Bank
AC400V-20kw Rack Mounted Load BankAC400V-20kw Rack Mounted Load Bank

Company Profile
Hebei Kaixiang Electrical Technology Co., Ltd(KX) is a leading manufacturer in emergency power supply test & maintenance industry. Specialized in the design, R&D, manufacture of the high capacity AC & DC load bank, it owns the largest Load Bank R & D centre in China. KX offer one-stop solutions to generator set & battery & UPS power manufacturers. Its products are widely used in data centre, shipbuilding, offshore platform, state grid, nuclear power, hospital, communication, railway, war industry etc field.

AC400V-20kw Rack Mounted Load Bank

1. Professional technical team with more than 20 years design experience.
2. Customer has the right of technical consulting service for free forever.
3. Drafters of load standards for the Marine industry
4. China's first ship load maximum power record holder
5. Reliable quality & competitive price help customers to maximize profits.
6. Strict inspection procedures throughout the whole production flow.
7. If required, technicians will be sent to help customer install and debug the machine. 8. Certified with CCS and ISO9001:2008 Quality Certificate.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier