  • Triumphload AC600V 800kw Load Bank for Generator Testing
  • Triumphload AC600V 800kw Load Bank for Generator Testing
  • Triumphload AC600V 800kw Load Bank for Generator Testing
  • Triumphload AC600V 800kw Load Bank for Generator Testing
  • Triumphload AC600V 800kw Load Bank for Generator Testing
  • Triumphload AC600V 800kw Load Bank for Generator Testing
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Exhibition
  • Equipment Site
  • Company Profile
Overview

Basic Info.

Model NO.
AC600V-800kW
Insulation
F
Working
Continuous Working
Color
Ral7035
Weight
About 1200kg
Display Precision
0.5
Communication Interface
RS485
Transport Package
Wooden Packaging
Specification
About 1820mm*1300mm*2038mm
Trademark
Triumph Load
Origin
Hebei
HS Code
9030339000
Production Capacity
15sets/Month

Product Description

Product Description

AC600V-800KW Load Bank
1)Control Mode: You can select the local or intelligent mode to control the load.

2)Local control: The load is equipped with a local control panel, and divided into a number of power gears, which can be controlled by the switch load control and view data parameters.
 
3)Intelligent control: control the load through the data management software on the computer, realize automatic loading, display, record and manage the test data, generate various curves and charts, and support printing.
 
4)Safety monitoring: Through software indicator light, load bank status can be visually monitored, and reason of shutdown will be prompted when protection is abnormally shut down.
 
5)Graphical display: Can show real-time or history testing data, and support to print following curves and graphs, etc. 1) Graphs of real-time voltage, current, frequency and power; 2) Voltage graph 3) Current graph; 4) Power graph; 5) Frequency graph; 6) Power factor graph
 
6)Quality factor test: The equipment can load different R, L, C power, complete the quality factor QF test, to meet the predetermined resonant test requirements, etc.
Detailed Photos

Triumphload AC600V 800kw Load Bank for Generator TestingTriumphload AC600V 800kw Load Bank for Generator TestingTriumphload AC600V 800kw Load Bank for Generator Testing

 

Product Parameters
Product
AC600V-800kW Intelligent Load Bank
Rating Voltage AC three-phase four-wire AC600V 50/60Hz
(compatible with 480V 220V)
Max Load Power
Resistive load:
800kW at 600V; About 512kW at 480V; About 107.5kW at 220V.
Load Step Resistive Load:12 steps 1,2,2,5,10,10,20,50,100,200,200,200kW.
Noted: When input voltage is lower than rated voltage, gears power changes according to Ohm's law.
Display precision Class 0.5
Load accuracy (per gear) ±5%
Load Tolerance (overall) ±3%
Wire Connection Load bank input--Copper bar (star connection)
Control power input--terminal block
Cooling Forced air cooling, side inlet, upper outlet
Transportation With lifting eyes and wheel castors at bottom
Color RAL 7035
Dimension About 1820mm×1300mm×2038mm (L × W × H)
Operating Environment Parameter
Work Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500M
Atmospheric Pressure 86~106kPa
 
Certifications

Triumphload AC600V 800kw Load Bank for Generator TestingTriumphload AC600V 800kw Load Bank for Generator Testing

Exhibition

Triumphload AC600V 800kw Load Bank for Generator TestingTriumphload AC600V 800kw Load Bank for Generator Testing

Equipment Site

Triumphload AC600V 800kw Load Bank for Generator Testing
Triumphload AC600V 800kw Load Bank for Generator TestingTriumphload AC600V 800kw Load Bank for Generator Testing

Company Profile
Kaixiang Technology was founded in 1994, focus on load 26 years! The Company is China's largest power testing and maintenance enterprise, the main power testing equipment research and development and manufacturing.
Kaixiang Technology is a Chinese high-tech enterprise, double soft certification enterprise, passed the ISO9001 international quality management system certification, CCS China Classification Society certification.The products have passed the EU CE certification, Russian Baiha EAC certification, and have been inspected by a number of testing institutions, and the technical indicators have met the requirements of quality standards. The company's current technical developers and technical service personnel account for more than 30%. It can provide users with full service from design, manufacturing, installation, commissioning, training to maintenance, as well as OEM/ODM, leasing and field testing services.

Triumphload AC600V 800kw Load Bank for Generator Testing

1. Professional technical team with more than 20 years design experience.
2. Customer has the right of technical consulting service for free forever.
3. Drafters of load standards for the Marine industry
4. China's first ship load maximum power record holder
5. Reliable quality & competitive price help customers to maximize profits.
6. Strict inspection procedures throughout the whole production flow.
7. If required, technicians will be sent to help customer install and debug the machine.
8. Certified with CCS and ISO9001:2008 Quality Certificate.

Send your message to this supplier