AC 200K Load Bank Rlc for Genset Testing

Product Details
Customization: Available
After-sales Service: Permanent
Warranty: 1years
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 8 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • AC 200K Load Bank Rlc for Genset Testing
  • AC 200K Load Bank Rlc for Genset Testing
  • AC 200K Load Bank Rlc for Genset Testing
  • AC 200K Load Bank Rlc for Genset Testing
  • AC 200K Load Bank Rlc for Genset Testing
  • AC 200K Load Bank Rlc for Genset Testing
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Exhibition
  • Equipment Site
  • Company Profile
Overview

Basic Info.

Model NO.
AC400V-200K
Insulation
F
Working
Continuous Working
Color
Ral7035
Rated Frequency
50Hz
Transport Package
Wooden Packaging
Specification
About 1500mm*2400mm*2400mm
Trademark
Triumph Load
Origin
Hebei
HS Code
9030339000
Production Capacity
15sets/Month

Product Description

Product Description

AC400V-200K RLC Load Bank
1)Control Mode: You can select the local or intelligent mode to control the load.

2)Local control: The load is equipped with a local control panel, and divided into a number of power gears, which can be controlled by the switch load control and view data parameters.
 
3)Intelligent control: control the load through the data management software on the computer, realize automatic loading, display, record and manage the test data, generate various curves and charts, and support printing.
 
4)Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.
 
5)Power loop control: The capacitive load control loop adopts anti-short circuit and anti-surge current protection measures. The inductive load is equipped with the user's anti-surge voltage measures, and the reliable protection module is used to control it, so as to avoid the failure of components during the test process and the instant the loading switch is closed and the host is burned.
 
6)Anti-island test: load resistive load, inductive load, capacitive load, carry out different proportions of matching modulation resonant frequency, through the load load power to achieve the resonance depth and QF value adjustment.
 
7)Programmable test: The RLC load test phase can be programmed to simulate different types of loads in the power grid, the equipment is automatically executed according to the set sequence, and the loading and running time can be set.
 
8)Island protection function: built-in resistive load, inductive load and capacitive load minimum standard power is 0.001kVA, step amplitude 0.001kVA, load power is continuously adjustable, can accurately simulate AC resonance occurrence and meet the inverter anti-island protection function detection needs.
 
9)Quality factor test: The equipment can load different R, L, C power, complete the quality factor QF test, to meet the predetermined resonant test requirements, etc.
Detailed Photos
AC 200K Load Bank Rlc for Genset TestingAC 200K Load Bank Rlc for Genset Testing
AC 200K Load Bank Rlc for Genset Testing

 

Product Parameters
Product
AC400V-200k Dummy Load Bank
Rating Voltage AC three-phase four-wire AC400V(L-L)/50Hz
or single AC230V(L-N)/50Hz
Max Load Power 200k
Rated Power
AC400V/50Hz
Resistance: 204.33kW
Sensibility: 204.33kvar
Capacity: 204.33kvar
Load Step Resistive load:
Single-phase independent part: each phase gear is divided into: 0.001, 0.002, 0.002, 0.005, 0.01, 0.02, 0.02, 0.05, 0.1, 0.2, 0.2, 0.5, 1, 2, 2, 5, 5, 10, 20, 20kW, the minimum step value is 0.001kW, each phase is 68.11kW, the total of the three phases is 204.33kW.
Inductive load:
Single-phase independent part: each phase gear is divided into: 0.001, 0.002, 0.002, 0.005, 0.01, 0.02, 0.02, 0.05, 0.1, 0.2, 0.2, 0.5, 1, 2, 2, 5, 5, 10, 20, 20kvar, minimum step value 0.001kvar, 68.11kvar per phase, The three phases add up to 204.33kvar.
Capacitive load:
Single-phase independent part: each phase gear is divided into: 0.001, 0.002, 0.002, 0.005, 0.01, 0.02, 0.02, 0.05, 0.1, 0.2, 0.2, 0.5, 1, 2, 2, 5, 5, 10, 20, 20kvar, minimum step value 0.001kvar, 68.11kvar per phase, The three phases add up to 204.33kvar.
Load Tolerance  Resistance: cold ±3%, hot ±1.5%, combined ±3%
Capacitance: cold ±3%, hot ±0.1%, combined ±3%
Inductance: cold ±3%, hot ±0.1%, combined ±3%
Display precision Class 0.5
Control Power Supply External AC230V single-phase 50Hz/60Hz
Wire Connection Three-phase four-wire Yn type connection, with A, B, C, N a total of four terminals;
Single-phase two-wire system can be connected to A, N; B, N; C or N.
Phase Voltage Measurement The voltage measurement accuracy is ±0.2% and the voltage resolution is 0.1V
Current Measurement The current measurement accuracy is ±0.2% and the current resolution is 0.1A
Wattful Power Measurement The power measurement accuracy is ±0.5% and the power resolution is 0.001kW
Wattless Power Measurement The power measurement accuracy is ±0.5% and the power resolution is 0.001kvar
Cooling Forced air cooling, side inlet, upper outlet
Transportation With lifting eyes and wheel castors at bottom
Color RAL 7035
Dimension About 1500mm×2400mm×2400mm (L × W × H)
Operating Environment Parameter
Work Temperature -15ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500M
Atmospheric Pressure 86~106kPa
 
Certifications

AC 200K Load Bank Rlc for Genset TestingAC 200K Load Bank Rlc for Genset Testing

Exhibition

AC 200K Load Bank Rlc for Genset TestingAC 200K Load Bank Rlc for Genset Testing

Equipment Site

AC 200K Load Bank Rlc for Genset Testing
AC 200K Load Bank Rlc for Genset TestingAC 200K Load Bank Rlc for Genset Testing

Company Profile
Kaixiang Technology was founded in 1994, focus on load 26 years! The Company is China's largest power testing and maintenance enterprise, the main power testing equipment research and development and manufacturing.
Kaixiang Technology is a Chinese high-tech enterprise, double soft certification enterprise, passed the ISO9001 international quality management system certification, CCS China Classification Society certification.The products have passed the EU CE certification, Russian Baiha EAC certification, and have been inspected by a number of testing institutions, and the technical indicators have met the requirements of quality standards. The company's current technical developers and technical service personnel account for more than 30%. It can provide users with full service from design, manufacturing, installation, commissioning, training to maintenance, as well as OEM/ODM, leasing and field testing services.

AC 200K Load Bank Rlc for Genset Testing

1. Professional technical team with more than 20 years design experience.
2. Customer has the right of technical consulting service for free forever.
3. Drafters of load standards for the Marine industry
4. China's first ship load maximum power record holder
5. Reliable quality & competitive price help customers to maximize profits.
6. Strict inspection procedures throughout the whole production flow.
7. If required, technicians will be sent to help customer install and debug the machine.
8. Certified with CCS and ISO9001:2008 Quality Certificate.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier