380V 400kw Resistive AC Load Bank for Generator Testing

Product Details
Customization: Available
After-sales Service: 3months-1year
Application: Electrical & Electronics
Gold Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 14 foreign trading staff(s) and 8 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (25)
  • 380V 400kw Resistive AC Load Bank for Generator Testing
  • 380V 400kw Resistive AC Load Bank for Generator Testing
  • 380V 400kw Resistive AC Load Bank for Generator Testing
  • 380V 400kw Resistive AC Load Bank for Generator Testing
  • 380V 400kw Resistive AC Load Bank for Generator Testing
  • 380V 400kw Resistive AC Load Bank for Generator Testing
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
380V 400kW
Power Factor
1
Workpalce
Outdoor
Max Load Power
400kw
Function
Generator Testing
Key Word
Load
Customized Support
OEM
Voltage
380V
Frequency
50/60Hz
Specification
About 600kg
Trademark
Triumph Load
Origin
China

Product Description

380V 400kW Resistive AC Load Bank for Generator Testing
Product Description

General introduction

Triumph load can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW.Resistive, inductive(reactive),capacitive or combined load banks can be customized for any application.
 
They can be used for testing numerous sets in a workshop environment, or used for on-site commissioning, witness tests and proof trials.Custom-built load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.
 
Triumph load are available in stationary type for permanent installation or portable type with fork lift pocket
base,castors.Larger load banks, typically above 1200kVA, are based on an ISO container construction. Special finishes including
custom paint colors and stainless steel casings can be supplied.

Main functions:

1.Users can set adjustable load power within rated power.
2.Current,voltage,frequency,power factor,and active power,reactive power ,and apparent power can be displayed.
3.With software programmable control,graphs og current,voltage,frequency,power factor,power can be displayed,saved and printed.
Control mode:manual control(control panel) with remote controller box or PC control.
Display meters: multi-function digital meter or generator tester.
Protection:Over load protection,over heat protection,short circuit protection,emergency stops switch,etc.

Product show
380V 400kw Resistive AC Load Bank for Generator Testing380V 400kw Resistive AC Load Bank for Generator Testing
Product Parameters
Technical Parameters
Rated Voltage
/Frequency
AC380V 3 phase 4 wire /50Hz,with 60Hz;
Max Load Power 400kW
Load Step
AC380V/50Hz
Resistive Load:10 steps,1,2,2,5,10,10,20,50,100,200kW
Noted: When input voltage is lower than rated voltage, gears power changes according to Ohm's law.
Power Factor 1
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Display Precision 0.5 class
Control Power Supply External:AC380V 3 phase 5 wire (A/B/C/N)/60Hz,
Wire Connection Load bank input--busbar (star coupling "Y")
Control power input--terminal block
Communication Interface RS232/ RS485
Insulation Class F Class
Working Mode Continuous Working
Cooling Forced air cooling, horizontal inlet and outlet,Air inlet and outlet with louvered frame and plate
Transportation With lifting eyes and wheel castors and forklift at bottom.(one-piece)
Casing Color Carter yellow
Dimension About 1820mm*1300mm*1190mm(W*L*H)
Weight About 600kg
Operating Environment Parameter
Workplace Outdoor
Work Temperature -20ºC~+50ºC
Relative Humidity ≤95%
Altitude ≤2500M
Atmospheric Pressure 86~106kPa
 
Company Profile

Company introduction

Hebei Kaixiang Electrical Technology Co.Ltd is a leading manufacturer in emergency power supply test & maintenance industry.Specialized in the design,R&D, manufacture of the capacity AC & DC load bank,it owns the largest intelligent power supply testing equipment R & D center in China.
 
The company's core technologies are independent research. There are ten patents,ten software copyrights and two corporate standards.It has been named the international advanced level scientific and technological achievements by Science and Technology Department of Hebei Province.
 
Kaixiang offer one-stop solutions to generator set & battery & UPS power manufacturers.Its products are widely used in data center,shipbuilding,offshore platform,state grid, nuclear power, hospital ,communication,railway,war industry etc filed.Kaixiang is strategy partner of many famous company,such as Cummins, Caterpillar, Kohler, Jiangnan Shipyard, CSSC,CSIC, State grid, China mobile, Tecent, Baidu, Sinopec, CETC etc. Some of its products have been exported to America, Singapore, Israel,Japan, United Kingdom, Saudi Arabia, Australia, South Korea,Thailand, Sri Lanka, Angola etc. Through years of development, "Triumph Load" already the first brand in power supply detection industry in China.

380V 400kw Resistive AC Load Bank for Generator Testing
Certifications

380V 400kw Resistive AC Load Bank for Generator Testing380V 400kw Resistive AC Load Bank for Generator Testing

Application

Large generator system testing in ocean enginerering,drilling facilities,ship construction etc
Factory testing for generator, static voltage characteristic test,speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test,
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test
Eliminate the carbon deposition of generator
As the generator loading system
Periodic running test for standby generator
UPS inspection and maintenance
Ship battery charging/discharging system testing 
The acceptance of new system and testing of servicing equipment
To reduce "wet stacking" problems

 
FAQ

Why choose us
1. Professional technical team with more than 20 years design experience.
2. Customized technical solutions meet customer's individual requirements.
3. Strict inspection procedures throughout the whole production flow.
4. Perfect after sales service create good user experience.
5. Reliable quality & competitive price maximize profits for customers.
6. Certified with CCS and ISO9001:2008 Quality Certificate.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier